基于环介导等温扩增技术的微流控芯片在病原菌检测方面的研究进展
作者:
基金项目:

国家重点研发计划(2017YFC1601200)


Advances in the detection of pathogenic bacteria by using loop-mediated isothermal amplification-based microfluidic chip
Author:
  • Yuting Shang

    Yuting Shang

    Guangdong Institute of Microbiology, Guangdong Academy of Sciences, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Safety and Health, Guangzhou 510070, Guangdong Province, China;State Key Laboratory of Food Science and Technology, National Engineering Research Centre for Functional Food, Synergetic Innovation Centre of Food Safety and Quality Control, School of Food Science and Technology, Jiangnan University, Wuxi 214122, Jiangsu Province, China
    在期刊界中查找
    在百度中查找
    在本站中查找
  • Qinghua Ye

    Qinghua Ye

    Guangdong Institute of Microbiology, Guangdong Academy of Sciences, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Safety and Health, Guangzhou 510070, Guangdong Province, China
    在期刊界中查找
    在百度中查找
    在本站中查找
  • Shuzhen Cai

    Shuzhen Cai

    Guangdong Institute of Microbiology, Guangdong Academy of Sciences, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Safety and Health, Guangzhou 510070, Guangdong Province, China
    在期刊界中查找
    在百度中查找
    在本站中查找
  • Qingping Wu

    Qingping Wu

    Guangdong Institute of Microbiology, Guangdong Academy of Sciences, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Safety and Health, Guangzhou 510070, Guangdong Province, China
    在期刊界中查找
    在百度中查找
    在本站中查找
  • Jumei Zhang

    Jumei Zhang

    Guangdong Institute of Microbiology, Guangdong Academy of Sciences, State Key Laboratory of Applied Microbiology Southern China, Guangdong Provincial Key Laboratory of Microbial Safety and Health, Guangzhou 510070, Guangdong Province, China
    在期刊界中查找
    在百度中查找
    在本站中查找
  • 摘要
  • | |
  • 访问统计
  • |
  • 参考文献 [54]
  • |
  • 相似文献 [20]
  • | | |
  • 文章评论
    摘要:

    环介导等温扩增(LAMP)技术是一种新兴的核酸恒温扩增技术,与微流控芯片技术相结合,可实现对病原菌的快速检测,具有特异性强、灵敏度高、操作简单等优点。本文根据不同终产物的检测方法对目前检测病原菌的相关微流控LAMP芯片进行了分类与介绍,并对技术的改进和存在的问题进行了分析,以期为后续的相关研究提供参考。

    Abstract:

    Loop-mediated isothermal amplification (LAMP) is an emerging nucleic acid amplification technique under isothermal condition, which can combined with microfluidic chip to rapidly detect the pathogenic bacteria. It is of higher specificity, higher sensitivity and simpler operation. This article classified and introduced the LAMP-based microfluidic chip for the detection of pathogenic bacteria, based on the analysis of different end-point detection methods. And also, we analyzed the improvement and existing problems of this technology, which can provide great reference value for the further studies and industry development.

    参考文献
    [1] Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Research, 2000, 28(12):e63.
    [2] Nagamine K, Hase T, Notomi T. Accelerated reaction by loop-mediated isothermal amplification using loop primers. Molecular and Cellular Probes, 2002, 16(3):223-229.
    [3] Chang CM, Chang WH, Wang CH, Wang JH, Mai JD, Lee GB. Nucleic acid amplification using microfluidic systems. Lab on a Chip, 2013, 13(7):1225-1242.
    [4] Kokkinos PA, Ziros PG, Bellou M, Vantarakis A. Loop-mediated isothermal amplification (LAMP) for the detection of Salmonella in food. Food Analytical Methods, 2014, 7(2):512-526.
    [5] Zhang SH, Xu XK, Wu QP, Zhang JM. Rapid and sensitive detection of Pseudomonas aeruginosa in bottled water by loop-mediated isothermal amplification. European Food Research and Technology, 2013, 236(1):209-215.
    [6] Xu X, Zhang S, Wu Q, Zhang J, Li F, Cheng J. Development and application of a loop-mediated isothermal amplification (LAMP) method for rapid and sensitive detection of Enterococcus faecalis in drinking water. Journal of Food Safety, 2014, 34(2):103-110.
    [7] Li N, Zhang YX, Wu QP, Gu QH, Zhang YZ, Wang JS, Sun XL, Zhang JM. Detection of Pseudomonas in pork by real-time fluorescence loop-mediated isothermal amplification method. Modern Food Science and Technology, 2019, 35(6):264-272. (in Chinese) 李宁, 张友雄, 吴清平, 古其会, 张银志, 王加生, 孙秀兰, 张菊梅. 实时荧光环介导等温扩增技术检测猪肉中的假单胞菌. 现代食品科技, 2019, 35(6):264-272.
    [8] Kou X, Fan H, Wu Q, Xue L, Zhang J. Development and application of a loop-mediated isothermal amplification assay on rapid and sensitive detection of rotavirus in fecal samples and artificially seeded oysters. Food Control, 2014, 41:151-157.
    [9] Yu MF, Zeng HM, Zhang H, Qiu DW. Research progress in microfluidics and its applications. Plant Protection, 2014, 40(4):1-8. (in Chinese) 余明芬, 曾洪梅, 张桦, 邱德文. 微流控芯片技术研究概况及其应用进展. 植物保护, 2014, 40(4):1-8.
    [10] Zhang XZ, Lowe SB, Gooding JJ. Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosensors & Bioelectronics, 2014, 61:491-499.
    [11] Fang XE, Liu YY, Kong JL, Jiang XY. Loop-mediated isothermal amplification integrated on microfluidic chips for point-of-care quantitative detection of pathogens. Analytical Chemistry, 2010, 82(7):3002-3006.
    [12] Chang W, Yang S, Lin C, Wang C, Li P, Chen T, Jan F, Lee G. Detection of viruses directly from the fresh leaves of a Phalaenopsis orchid using a microfluidic system. Nanomedicine:Nanotechnology, Biology and Medicine, 2013, 9(8):1274-1282.
    [13] Lin CL, Chang WH, Wang CH, Lee CH, Chen TY, Jan FJ, Lee GB. A microfluidic system integrated with buried optical fibers for detection of Phalaenopsis orchid pathogens. Biosensors & Bioelectronics, 2015, 63:572-579.
    [14] Seyrig G, Stedtfeld RD, Tourlousse DM, Ahmad F, Towery K, Cupples AM, Tiedje JM, Hashsham SA. Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics. Journal of Microbiological Methods, 2015, 119:223-227.
    [15] Fu ZF, Wang XF, Xu JF, Li YY. Research progress in detection and result determination of end products of loop-mediated isothermal amplification. Journal of Zhejiang Agricultural Sciences, 2016, 57(5):725-729. (in Chinese) 付振芳, 汪小福, 徐俊锋, 李玥莹. 环介导等温扩增终端产物检测及结果判断的研究进展. 浙江农业科学, 2016, 57(5):725-729.
    [16] Safavieh M, Kanakasabapathy MK, Tarlan F, Ahmed MU, Zourob M, Asghar W, Shafiee H. Emerging loop-mediated isothermal amplification-based microchip and microdevice technologies for nucleic acid detection. ACS Biomaterials Science & Engineering, 2016, 2(3):278-294.
    [17] Ahmad F, Seyrig G, Tourlousse DM, Stedtfeld RD, Tiedje JM, Hashsham SA. A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips. Biomedical Microdevices, 2011, 13(5):929-937.
    [18] Liu M, Zhao Y, Monshat H, Tang Z, Wu Z, Zhang Q, Lu M. An IoT-enabled paper sensor platform for real-time analysis of isothermal nucleic acid amplification tests. Biosensors and Bioelectronics, 2020, 169:112651.
    [19] Naik P, Jaitpal S, Shetty P, Paul D. An integrated one-step assay combining thermal lysis and loop-mediated isothermal DNA amplification (LAMP) in 30 min from E. coli and M. smegmatis cells on a paper substrate. Sensors and Actuators B:Chemical, 2019, 291:74-80.
    [20] Safavieh M, Ahmed MU, Sokullu E, Ng A, Braescu L, Zourob M. A simple cassette as point-of-care diagnostic device for naked-eye colorimetric bacteria detection. Analyst, 2014, 139(2):482-487.
    [21] Fang X, Chen H, Xu L, Jiang X, Wu W, Kong J. A portable and integrated nucleic acid amplification microfluidic chip for identifying bacteria. Lab Chip, 2012, 12(8):1495-1499.
    [22] Ji HS, Park BH, Oh SJ, Choi G, Kim DH, Lee EY, Seo TS. Development of a high-throughput centrifugal loop-mediated isothermal amplification microdevice for multiplex foodborne pathogenic bacteria detection. Sensors and Actuators B:Chemical, 2017, 246:146-153.
    [23] Oh SJ, Park BH, Jung JH, Choi G, Lee DC, Kim DH, Seo TS. Centrifugal loop-mediated isothermal amplification microdevice for rapid, multiplex and colorimetric foodborne pathogen detection. Biosensors & Bioelectronics, 2016, 75:293-300.
    [24] Duarte C, Salm E, Dorvel B, Reddy B, Bashir R. On-chip parallel detection of foodborne pathogens using loop-mediated isothermal amplification. Biomedical Microdevices, 2013, 15(5):821-830.
    [25] Santiagofelipe S, Tortajadagenaro LA, Carrascosa J, Puchades R, Maquieira A. Real-time loop-mediated isothermal DNA amplification in compact disc micro-reactors. Biosensors and Bioelectronics, 2016, 79:300-306.
    [26] Sayad A, Ibrahim F, Mukim Uddin S, Cho J, Madou M, Thong KL. A microdevice for rapid, Monoplex and colorimetric detection of foodborne pathogens using a centrifugal microfluidic platform. Biosensors & Bioelectronics, 2018, 100:96-104.
    [27] Tsougeni K, Kaprou G, Loukas CM, Papadakis G, Hamiot A, Eck M, Rabus D, Kokkoris G, Chatzandroulis S, Papadopoulos V, Dupuy B, Jobst G, Gizeli E, Tserepi A, Gogolides E. Lab-on-Chip platform and protocol for rapid foodborne pathogen detection comprising on-chip cell capture, lysis, DNA amplification and surface-acoustic-wave detection. Sensors and Actuators B:Chemical, 2020, 320:128345.
    [28] Chen C, Liu P, Zhao X, Du W, Feng X, Liu BF. A self-contained microfluidic in-gel loop-mediated isothermal amplification for multiplexed pathogen detection. Sensors and Actuators B:Chemical, 2017, 239:1-8.
    [29] Sayad AA, Ibrahim F, Uddin SM, Pei KX, Mohktar MS, Madou M, Thong KL. A microfluidic lab-on-a-disc integrated loop mediated isothermal amplification for foodborne pathogen detection. Sensors and Actuators B:Chemical, 2016, 227:600-609.
    [30] Uddin SM, Ibrahim F, Sayad AA, Thiha A, Pei KX, Mohktar MS, Hashim U, Cho J, Thong KL. A portable automatic endpoint detection system for amplicons of loop mediated isothermal amplification on microfluidic compact disk platform. Sensors, 2015, 15(3):5376-5389.
    [31] Xia Y, Liu Z, Yan S, Yin F, Feng X, Liu BF. Identifying multiple bacterial pathogens by loop-mediated isothermal amplification on a rotate and react slipchip. Sensors and Actuators B:Chemical, 2016, 228:491-499.
    [32] Zhou QJ, Wang L, Chen J, Wang RN, Shi YH, Li CH, Zhang DM, Yan XJ, Zhang YJ. Development and evaluation of a real-time fluorogenic loop-mediated isothermal amplification assay integrated on a microfluidic disc chip (on-chip LAMP) for rapid and simultaneous detection of ten pathogenic bacteria in aquatic animals. Journal of Microbiological Methods, 2014, 104:26-35.
    [33] Jiang XR, Jing WW, Sun XT, Liu Q, Yang CG, Liu SX, Qin KR, Sui GD. High-throughput microfluidic device for LAMP analysis of airborne bacteria. ACS Sensors, 2016, 1(7):958-962.
    [34] Dou MW, Sanjay ST, Dominguez DC, Liu P, Xu F, Li XJ. Multiplexed instrument-free meningitis diagnosis on a polymer/paper hybrid microfluidic biochip. Biosensors & Bioelectronics, 2017, 87:865-873.
    [35] Wang H, Ma Z, Qin JX, Shen Z, Liu Q, Chen XY, Wang HL, An ZH, Liu W, Li M. A versatile loop-mediated isothermal amplification microchip platform for Streptococcus pneumoniae and Mycoplasma pneumoniae testing at the point of care. Biosensors & Bioelectronics, 2019, 126:373-380.
    [36] Chang WH, Yang SY, Wang CH, Tsai MA, Wang PC, Chen TY, Chen SC, Lee GB. Rapid isolation and detection of aquaculture pathogens in an integrated microfluidic system using loop-mediated isothermal amplification. Sensors and Actuators B:Chemical, 2013, 180(10):96-106.
    [37] Patterson AS, Hsieh K, Soh HT, Plaxco KW. Electrochemical real-time nucleic acid amplification:towards point-of-care quantification of pathogens. Trends in Biotechnology, 2013, 31(12):704-712.
    [38] Luo J, Fang XE, Ye DX, Li HX, Chen H, Zhang S, Kong JL. A real-time microfluidic multiplex electrochemical loop-mediated isothermal amplification chip for differentiating bacteria. Biosensors & Bioelectronics, 2014, 60:84-91.
    [39] Hsieh K, Patterson AS, Ferguson BS, Plaxco KW, Soh HT. Rapid, sensitive, and quantitative detection of pathogenic DNA at the point of care through microfluidic electrochemical quantitative loop-mediated isothermal amplification. Angewandte Chemie:International Ed in English, 2012, 51(20):4896-4900.
    [40] Kampeera J, Pasakon P, Karuwan C, Arunrut N, Sappat A, Sirithammajak S, Dechokiattawan N, Sumranwanich T, Chaivisuthangkura P, Ounjai P, Chankhamhaengdecha S, Wisitsoraat A, Tuantranont A, Kiatpathomchai W. Point-of-care rapid detection of Vibrio parahaemolyticus in seafood using loop-mediated isothermal amplification and graphene-based screen-printed electrochemical sensor. Biosensors and Bioelectronics, 2019, 132:271-278.
    [41] Jaroenram W, Kampeera J, Arunrut N, Karuwan C, Sappat A, Khumwan P, Jaitrong S, Boonnak K, Prammananan T, Chaiprasert A, Tuantranont A, Kiatpathomchai W. Graphene-based electrochemical genosensor incorporated loop-mediated isothermal amplification for rapid on-site detection of Mycobacterium tuberculosis. Journal of Pharmaceutical and Biomedical Analysis, 2020, 186:113333.
    [42] Safavieh M, Ahmed MU, Zourob M. High throughput low cost electrochemical device for S.aureus bacteria detection. Sensors, 2013:1-4.
    [43] Safavieh M, Ahmed MU, Ng A, Zourob M. High-throughput real-time electrochemical monitoring of LAMP for pathogenic bacteria detection. Biosensors & Bioelectronics, 2014, 58:101-106.
    [44] Zhu ZH, Ge LY, Tu XB, Yu CT, Huang XD, Bian XH, Qi S, Zhang H. Progress on application of isothermal amplification for food-borne pathogen detection. Journal of Food Safety and Quality, 2015(12):4787-4794. (in Chinese) 朱智壕, 葛丽雅, 涂晓波, 余超挺, 黄欣迪, 卞学海, 亓双, 张恒. 等温扩增技术在食源性致病菌检测中的应用进展. 食品安全质量检测学报, 2015(12):4787-4794.
    [45] Park BH, Oh SJ, Jung JH, Choi G, Seo JH, Kim DH, Lee EY, Seo TS. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics. Biosensors & Bioelectronics, 2017, 91:334-340.
    [46] Wang CH, Lien KY, Wu JJ, Lee GB. A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loop-mediated isothermal amplification. Lab on a Chip, 2011, 11(8):1521-1531.
    [47] Liu CC, Geva E, Mauk M, Qiu XB, Abrams WR, Malamud D, Curtis K, Owen SM, Bau HH. An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases. The Analyst, 2011, 136(10):2069-2076.
    [48] Wu QQ, Jin W, Zhou C, Han SH, Yang WX, Zhu QY, Jin QH, Mu Y. Integrated glass microdevice for nucleic acid purification, loop-mediated isothermal amplification, and online detection. Analytical Chemistry, 2011, 83(9):3336-3342.
    [49] Guo Z, Yu T, He JR, Liu F, Hao HL, Zhao Y, Wen JB, Wang Q. An integrated microfluidic chip for the detection of bacteria-A proof of concept. Molecular and Cellular Probes, 2015, 29(4):223-227.
    [50] Loo JF, Kwok HC, Leung CC, Wu SY, Law IL, Cheung YK, Cheung YY, Chin ML, Kwan P, Hui M. Sample-to-answer on molecular diagnosis of bacterial infection using integrated lab-on-a-disc. Biosensors and Bioelectronics, 2017, 93:212-219.
    [51] Liu D, Zhu Y, Li N, Lu Y, Cheng J, Xu Y. A portable microfluidic analyzer for integrated bacterial detection using visible loop-mediated amplification. Sensors and Actuators B:Chemical, 2020, 310:127834.
    [52] Ma YD, Chang WH, Luo K, Wang CH, Liu SY, Yen WH, Lee GB. Digital quantification of DNA via isothermal amplification on a self-driven microfluidic chip featuring hydrophilic film-coated polydimethylsiloxane. Biosensors & Bioelectronics, 2018, 99:547-554.
    [53] Rodriguez-Manzano J, Karymov MA, Begolo S, Selck DA, Zhukov DV, Jue E, Ismagilov RF. Reading out single-molecule digital RNA and DNA isothermal amplification in nanoliter volumes with unmodified camera phones. ACS Nano, 2016, 10(3):3102-3113.
    [54] Rane TD, Chen L, Zec HC, Wang TH. Microfluidic continuous flow digital loop-mediated isothermal amplification (LAMP). Lab Chip, 2015, 15(3):776-782.
    引证文献
    网友评论
    网友评论
    分享到微博
    发 布
引用本文

尚玉婷,叶青华,蔡淑珍,吴清平,张菊梅. 基于环介导等温扩增技术的微流控芯片在病原菌检测方面的研究进展[J]. 微生物学报, 2021, 61(10): 2999-3009

复制
分享
文章指标
  • 点击次数:461
  • 下载次数: 1150
  • HTML阅读次数: 1205
  • 引用次数: 0
历史
  • 收稿日期:2020-12-22
  • 最后修改日期:2021-01-20
  • 在线发布日期: 2021-09-29
文章二维码